EMS61000-4A Intelligent Electrical Fast Transient Generator
EMS61000-4A Intelligent Electrical Fast Transient Generator is suitable for electrical fast transient impulse group immunity test occasions. It simulates the interference caused by many mechanical switches (switching inductive loads, relay contact bouncing, etc.) in power grid. It has good transient pulse waveform, high pulse repetition rate (up to 2MHz), stable performance, easy operation, fully conforms to the latest IEC (International Electrotechnical Commission) standard IEC 61000-4-4, European electrical standard EN61000-4-4, and national standard GB/T17626.4. It is an ideal interference source for EMC test.
Characteristics
- 10.1 inch color touch-screen display, intelligent and efficient;
- Programmableboost, test voltage peak is up to 5kV, frequency to 1MHz ( can be customized to 2MHz);
- The user can edit the test program by himself, the instrument can complete the test automatically according to the predetermined program, and support USB import and export, save, modify and call the function of the test program;
- The test voltage, pulse frequency and phase are automatically cruised and tested to find the failure sensitive point of the sample.
- Built in three-phase power supply line coupling decoupling network to fullyautomatically switch the coupling path.
- Built in voltage and current differential probe to display voltage and current of EUT in real time.
- Trigger signal output, external trigger input, EUT failure detection, external source synchronization and other extended functions.
- Automatically generate test reports, and support USB import and export.
Technical Specifications
|
Test voltage |
0.25kV~5.0kV(Higher voltage can be customized) |
|
Pulse repetition frequency |
0.1kHz~1MHz±3%( can be customized to 2MHz) |
|
Polarity |
Positive/Negative/Automatic Alternate |
|
Dynamic source impedance |
50Ω±2%、1000Ω±2%、Parasitic capacitance≤6pF |
|
Single pulse waveform parameters on 50Ω load |
Rising time(10%-90%):5ns±30% Duration time(50%-50%):50ns±30% |
|
Single pulse waveform parameters on 1000Ω load |
Rising time(10%-90%):5ns±30% Duration time(50%-50%):35ns~150ns |
|
Number of pulses per pulse group |
1~255:(Pulse repetition frequency 0.1kHz-100kHz) 10~255(Pulse repetition frequency 101kHz-1MHz) |
|
Self setting of pulse group period |
20ms~99999ms±5% |
|
Test time setting |
1s ~99999s |
|
Test load impedance |
50W,1000W |
|
Parasitic capacitance |
≤6pF |
|
Septum capacitance |
10nF |
|
Phase synchronization |
0-359° phase synchronization / power synchronization / asynchronism |
|
Power supply of tested equipment Built in three-phase coupling network |
AC:0~260V(50Hz/60Hz)Maximum allowed continuous current 20A DC:0~220V,Maximum allowed continuous current 20A When the tested equipment and power supply network are disconnected, the residual test pulse voltage at the input end of the coupled/decoupled network does not exceed 10% of the applied test voltage. |
|
Communication function |
RJ45 communication interface, through the host computer remote control equipment to complete the test. |